BR-DC100 DIN-rail breaker

DMX Power Catalog

DIN Mount Breaker

Accessory

Discontinued

No replacement

Still running one? Find a service center or call +1-800-553-6418

DC circuit breakers that clip onto the DIN rail inside the MP (Magnum Panel) and MMP (Mini Magnum Panel) enclosures, providing overcurrent protection and a disconnect for charge controllers and DC loads. Each takes a 1" opening in the panel's front cover.

Overview

  • BR-DC…-DIN — two-pole parallel breaker rated 125 VDC, with wire terminals at each end. Wire 14–1/0 AWG, torque 28 in-lb.
  • BR-PV…-DIN — two-pole series breaker rated 250 VDC, with pressure terminals at one end; used between a PV array and the charge controller. Wire 18–2 AWG, torque 20 in-lb.

Hydraulic-magnetic and 100% rated. UL489A listed, VDE (EN 60947-2) approved and CE certified. The terminals need solid wire or a ferrule. The breakers are polarity sensitive and must be mounted vertically — see the instruction sheet before wiring.

Models

  • BR-PV10-DIN — 10 amps, 250 VDC, DIN Mount.
  • BR-PV15-DIN — 15 amps, 250 VDC, DIN Mount.
  • BR-PV20-DIN — 20 amps, 250 VDC, DIN Mount.
  • BR-PV30-DIN — 30 amps, 250 VDC, DIN Mount.
  • BR-PV40-DIN — 40 amps, 250 VDC, DIN Mount.
  • BR-PV50-DIN — 50 amps, 250 VDC, DIN Mount.
  • BR-DC100-DIN — 100 amps, 125 VDC, DIN Mount.

Works with

  • MMP Panel System
  • MPSL Panel System
  • MPSH Panel System
  • MPDH Panel System
  • MMP-E Panel System
  • MPSL-PE Panel System
  • MPDH-PE Panel System
  • MPX Kits
  • MPX-PE Kits

Models & Specifications

Full specifications for every model.

Model Amperage Manual Warranty
BR-PV10-DIN Discontinued 10 A
BR-PV15-DIN Discontinued 15 A
BR-PV20-DIN Discontinued 20 A
BR-PV30-DIN Discontinued 30 A
BR-PV40-DIN Discontinued 40 A
BR-PV50-DIN Discontinued 50 A
BR-DC100-DIN Discontinued 100 A